Silicon Carbon 420 Anode Sheet (SC0101) Single-sided, 5 pieces/pack

Original price was: $188.00.Current price is: $47.00.

SKU: sg-14830524399776 Category:

Silicon Carbon 420 Anode Sheet (SC0101) Single-sided, 5 pieces/pack

Product Name & Description

Silicon Carbon 420 Electrode Sheet (SC0101) is based on Copper foil coated by Silicon Carbon 420 Electrode Sheet (SC0101) on a single side and can be used as lithium ion battery.

    Initial Charge and Discharge Test Conditions:

    • Temperature: 25°C
    • Charge: First, charge at a constant current of 0.1C to 2.0V,
    • Discharge: Discharge at a constant current of 0.1C/0.09C/0.08C/0.07C/0.06C/0.05C/0.04C/0.03C/0.02C/0.01C stages down to 0.005V.

    Rate Performance Test Conditions:

    • Temperature: 25°C

    • Charge: First, charge at a constant current at 0.1C/0.2C/0.5C/1C/2C/3C rates up to 2.0V.
    • Discharge: Discharge at constant current rates of 1C/0.9C/0.8C/0.7C/0.6C/0.5C/0.4C/0.3C/0.2C/0.1C stages down to 0.005V.

    Cycle Test Conditions:

    • Temperature: 25°C
    • Charge: First, charge at a constant current of 0.5C to 2.0V.
    • Discharge: Discharge at a constant current of 1C/0.9C/0.8C/0.7C/0.6C/0.5C/0.4C/0.3C/0.2C/0.1C stages down to 0.005V.

    .The electrolyte used corresponding to the performance data is silicon carbon-electrolyte (KLD-Si01).

    Specification

    Material

    Silicon carbon 420

    Sheet Size (cm)

    10*10

    Current Collector Thickness (μm)

    8

    Current Collector Areal Density (mg/cm2)

    7.3

    Coating Areal Density (mg/cm2)

    4.4 – 4.8 mg/cm² (subject to slight batch variation)

    Active Material Specific Capacity (mAh:g)

    420mAh/g (0.05-2.0V)

    Active Material Ratio (%)

    95.0

    Recommended Compaction Density (g/cc)

    1.3~1.55

    Test Conditions 
    (Room Temperature 25 ℃)

    0.1/0.1C, 0.05-2.0V

    Shelf Life

    1 year (vacuum sealed storage),
    use within 1 month after opening

    Instructions For Use

    1. The electrode calendering, needs to be calendered according to the recommended compaction density.
    2. The surface density needs to be determined based on the actual weighing results.
    3. Before placing it in the glove box, the electrodes needs to be vacuum dried at 105 ℃ for 4 hours

    Note: Since the electrodes are single-side-coated, calendering may cause curling issues. 

     

    Download Material Safety Data Sheet:


    Download Technical Data Sheet:

    Size